PLATFORM WILL NOT LOWER
1. Try lowering platform (activate
DOWN toggle switch). Only the
motor solenoid, “B” solenoid
valve and “C” solenoid valve
(located in the pump box)
(FIG. 82-1) and “D” solenoid
valve (on top of LH and RH
columns) (FIG. 82-2) should
be energized while lowering
platform. The “A” and “E”
solenoid valves should not be
energized. Connect voltmeter
to terminal-1 and terminal-2
on each valve shown in FIG.
82-1. Correct indication for
“A” and “E” solenoid valves
is 0 volts dc. For “B”, “C” and
“D” solenoid valves correct
indication is +11 to +12.6
volts dc. If any indications are
incorrect, check control switch
and wiring to that valve (refer
to ELECTRICAL SYSTEM
DIAGRAMS section). Replace
faulty wiring or control switch
as required.
“D” VALVE
FIG. 82-2
“D” VALVE
TROUBLESHOOTING - POWER DOWN
NOTE: For dual pump system, check secondary pump and motor fi rst.
NOTE: Numbers for the electrical terminals shown in the illustration are
not stamped on valve coil. Numbers shown are for reference only.
POWER DOWN PUMP
FIG. 82-1
“E” VALVE
(3-WAY)
MOTOR
SOLENOID
“C” VALVE
“B” VALVE
“A” VALVE
TYPICAL
TERMINAL-1
TYPICAL
TERMINAL-2